Vibratory sieve shaker as 200 basic retsch short sieving. The retsch as200 control g is used mainly in research and development, quality control of raw materials, intermediate products and finished products, as well as for production monitoring. All persons concerned with this device in any form. Sieve shaker retsch as 200 control 20um minimum particle size, 25mm maximum particle size, 3mm maximum amplitude, digital control, electromagnetic sieving motion, suitable for 100mm, 150mm, 200mm, 203mm and 8 sieves, with controlled amplitude and usb connection, clamping device, test sieves and collecting pan not included and must be ordered. This manual is a technical guide on how to operate the device safely and it contains all the information required for the areas specified in the table of contents.
Manualslib has more than 65 retsch manuals checkout popular retsch categories. Retsch 100 years of innovation global market leader in the preparation and characterization of solids quality made in germany. The as 200 control can be calibrated to ensure 100% reproducibility of sieving results, not only in one device, but among all as 200 control units. A few years later he registered his first patent in grinding technology. The software is able to automatically control the necessary.
Seite 1 bedienungsanleitung siebmaschine typ as 200 control retsch gmbh, 42781 haan, retsch allee 15, germany, 23. Sieve shaker retsch as 200 control 45um minimum particle size, 63mm maximum particle size, 300rpm maximum speed, digital control, horizontal circular sieving motion, suitable for 100mm, 150mm, 200mm, 203mm, 315mm, 400mm and 8 sieves, with controlled amplitude and no usb connection, clamping device, test sieves and collecting pan not included and must be ordered separately. Sieve shaker retsch as 200 control 20um minimum particle size, 25mm maximum particle size, 3mm maximum amplitude, digital control, electromagnetic sieving motion, suitable for 100mm, 150mm, 200mm, 203mm and 8 sieves, with controlled amplitude and usb connection, clamping device, test sieves and collecting pan not included and must be ordered separately. Retsch as 200 control natural frequency user manual 32 pages. Vibratory sieve shaker as 200 basic ats scientific. The rm 200 is suitable for the proper and reproduci. The as 200 tap is an ultramodern, highly efficient product of retsch gmbh, corresponding to state of the art. Wet sieving analysis this procedure was moderately developed as an intention of standardizing the particle size analysis in feed pellets for pellet quality project pqp that has taken place at umb.
Operating instructions as200 analytical sieve shakers. They give instructions to the target groups defined in the respective sections for safe, correct handling of the as 200 control. Sieves standardized retsch sieves for retsch as 200 control machine. The retsch representative in your country your supplier retsch gmbh directly your service address. Wet sieving procedure on a retsch as 200 control for feed manufactured pellets or feed compound procedure manual subject. Sieve shaker retsch as 200 control 20um minimum particle size, 25mm maximum particle size, 3mm maximum amplitude, digital control, electromagnetic.
Safety instructions as operating authority it is your duty to ensure that all. Retsch as200 operating instructions manual pdf download. Retsch as 200 user manual 36 pages manuals directory. This device is a modern, high performance product from retsch gmbh and complies with the state of the art. Once the source of the interference is eliminated, the as 200 digit ca will return to normal operation by itself. Vibratory sieve shaker 57 pages laboratory equipment retsch bb50 manual. It now comes with a natural frequency drive that not only takes sample loads of up to 6 kgs, but also can be operated from 100240 volts, 50 or 60 hz. As 200 basic retsch pdf catalogs technical documentation.
Operation manual air jet sieving machine typ as 200 jet. Consult retsch s entire as 200 basic catalogue on medicalexpo. The as 200 series provides a suitable instrument for every requirement and budget. Retsch gmbh 42781 haan, retsch allee 15, 272012 0002.
Strong electromagnetic interference fields, such as highpower radio transmitters, can have an adverse influence on the amplitude control of the as 200 digit ca. Retsch gmbh 42781 haan, retschallee 15, 272012 0002. Retsch shaker sieve as200 con 100240 300180001 is one of the many quality laboratory and scientific products we have to offer at very competitive pricing. Universal clamping lid with small window, for test sieves 100150 200 203 mm o rods, smooth, 2 pieces, for clamping device. Operating instructions for sieving machine type as 200 control. Sieve shaker as 200 control retsch precise sieve analysis. Combining excellent quality with an affordable price, the retsch shaker sieve as200 con 100240 300180001 66005038 can meet your scientific research needs while still offering a good value for a budget conscious end user. Accordingly, this model is perfectly suited to check particle size distributions for quality control, for example between suppliers and customers. On this page you will find pdf downloads of retsch operating instructions. Read the manual nonobservance of the manual the nonobservance of this manual can result in personal injuries. This document revision 0006 refers to the manual vibra tory sieve shaker as 200 basic in compliance with the directive of machinery 200642ec.
The as 200 tap can be used as testing equipment for quality control. Drying apparatus suitable oven for drying the sample on 104c eu 793. Glen mills powder mixing, milling, and particle reduction. Sieve shaker retsch as 200 control 45um minimum particle size, 63mm maximum particle size, 300rpm maximum speed, digital control, horizontal circular sieving motion, suitable for 100mm, 150mm, 200mm, 203mm, 315mm, 400mm and 8. While the as 300 control is designed for large feed quantities up to. Temperature control is effected using he display gauge. We use the adjacent symbol to draw attention to the necessity of knowing the contents of this operating manual. The sieve shaker as 200 control is suitable for dry and wet sieving. Easysieve, the software for particle size analyses, exceeds manual evaluation in many. This operating manual does not contain any repair instructions. Retsch test sieves are available in many sizes and varieties, primarily in the four frame sizes most widely used in laboratory analytics. Shows the cycling interval, from 1 to 99 seconds if the r. Retsch air jet sieving machine, as200 jet fisher scientific. The as200 is a modern, highly efficient product of retsch.
For your own safety, repairs may only be carried out by retsch gmbh or an authorized representative or by retsch service engineers. Operating instructions for tap sieving machine type as200 tap. Retsch calibration certificates confirm a great number of precision measurements, thus ensuring an even higher statistical reliability for your quality control. In this process the uniform, ro tating sieve movement and the tapping impulse guarantees exact separation of the material to be sieved, with a charged grain size of up to max. It is important that each target group or groups is are familiar with the relevant section, in. Sharp fractions are obtained even after short sieving times.
The controllable electromagnetic drive offers an optimal adaption for every product. Procedure sample preparation obtain a representative feed pellets sample that will be tested min. The retsch as 200 tap is used for dry sieving with analytical sieves of. The retsch as 200 tap is used for dry sieving with analytical sieves of diameter up to 203 mm. The mortar grinder rm 200 can mix and homogenize powders, suspension and pastes even with high viscosity. Measuring range 20 mm to 25mm height of sieve stack up to 450 mm, o100150 200 203 mm indication of sieve base acceleration and vibration height available in 3 different models, basic, digit and control choice of 3 lid clamping devices. As 300 control laboratory equipment pdf manual download. Easysieve, the software for particle size analyses, exceeds manual evaluation in many aspects. Consult retschs entire as 200 basic catalogue on medicalexpo. This drive produces a 3d throwing motion that moves the product to be sieved equally over the whole.
This technical documentation is a reference and instruction manual. View and download retsch as 300 control manual online. Read the manual nonobservance of the operating instructions the nonobservance of this manual can result in personal injuries. Standard wet sieving analysis fortek norwegian university. Analytical sieve shakers as 200 basicdigit control, as 300 control, as 450 basic, as 450 control analytical sieve shakers as 200, 300, 400, 450 analytical sieve shakers as 400 control, as 200 tap jet. This sieve machine can be used for the following materials. If the machine is used according to the intended purpose with a knowledge of this technical documentation it is completely safe and reliable to operate. Machines as 200 basic sieve shaker analogue controls. The as 400 control is used for the sieving of dry goods with test sieves of a diameter up to 400 mm.
In the download section of our website you will find files like brochures, operating manuals, magazine articles or our customer magazine. Sample divider 36 pages laboratory equipment retsch mm 500 vario manual. It is important that each target group or groups is. Retsch as 200 control bedienungsanleitung pdfherunterladen. As 200 control with clamping device comfort and sieve stack vibratory sieve shaker as 200 control all sieve shakers of the series as 200, as 300 and as 450 work with an electromagnetic drive that is patented by retsch ep 0642844. Retsch shaker sieve as200 con 100240 300180001 66005038 is part of a wide selection of retsch overhead stirrers.
Technical and software based modifications are reserved. Sieve shaker as 200 control from retsch gmbh selectscience. Laboratory equipment retsch as 200 tap manual 43 pages. Appreciated by an increasing number of customers in quality control departments, retsch s as 200 control has been redesigned as of early 2005. In this, the uniform, horizontal circular motion ensures exact separation of fine and coarsegrained products.
Combining excellent quality with an affordable price, the retsch shaker sieve as200 con 100240 300180001 66005038. Retsch as 300 control manual pdf download manualslib. Jaw crusher 44 pages laboratory equipment retsch pt100 manual. Analytical sieve shaker as 200 digit retsch quality and. All persons concerned with the machine in any form this machine is a modern, high performance product from retsch gmbh and complies with the state of the art. Operation manuals for all active mills and sieve shakers are available. Lever, green when pressed repeatedly, it moves the sieve fixing cover b downward, thus fixing the sieve stack. B strong electromagnetic interference fields, such as highpower radio transmitters, can have an adverse influence on the amplitude control of the as 200 basic. Sieve shaker spare parts and accessories lab unlimited.